1 – Latching Arm in AWAY Mode
The system is armed in AWAY Mode when using the latching keyswitch input. Disarming the
system is not permitted from the Keyswitch Zone.
2 – Latching Disarm from AWAY Mode, STAY Mode1, or STAY Mode 2
The system is disarmed from AWAY Mode, STAY Mode 1, or STAY Mode 2 when using the
latching keyswitch input. Arming the system is not permitted from the Keyswitch Zone.
4 – Latching Arm and Disarm in STAY Mode 1
The system is armed or disarmed in STAY Mode 1 when using the latching keyswitch input.
Arming and disarming the system in AWAY Mode is not permitted from the Keyswitch Zone.
5 – Latching Arm in STAY Mode 1
The system is armed in STAY Mode 1 when using the latching keyswitch input. Arming the
system in AWAY Mode or disarming the system is not permitted from the Keyswitch Zone.
6 – Latching Disarm from STAY Mode 1 or STAY Mode 2
The system is disarmed from STAY Mode 1 or STAY Mode 2 when using the latching keyswitch
input. Arming the system in STAY Mode 1 or STAY Mode 2, or arming and disarming the system
in AWAY Mode is permitted from the Keyswitch Zone.
8 – Momentary Arm and Disarm in AWAY Mode
The system is armed or disarmed from AWAY Mode when using the momentary keyswitch
input.
9 – Momentary Arm in AWAY Mode
The system is armed in AWAY Mode when using the momentary keyswitch input. Disarming the
system is not permitted from the Keyswitch Zone.
10 – Momentary Disarm from AWAY Mode, STAY Mode 1, or STAY Mode 2
The system is disarmed from either AWAY Mode, STAY Mode 1, or STAY Mode 2 when using
the momentary keyswitch input. Arming the system is not permitted from the Keyswitch Zone.
12 – Momentary Arm and Disarm in STAY Mode 1
The system is armed or disarmed in STAY Mode 1 when using the momentary keyswitch input.
Arming and disarming the system in AWAY Mode is not permitted from the Keyswitch Zone.
13 – Momentary Arm in STAY Mode 1
The system is armed in STAY Mode 1 when using the momentary keyswitch input. Arming the
system in AWAY Mode or disarming the system is not permitted from the Keyswitch Zone.
14 – Momentary Disarm from STAY Mode 1 or STAY Mode 2
The system is disarmed from STAY Mode 1 or STAY Mode 2 when using the momentary
keyswitch input. Arming the system in STAY Mode 1 or STAY Mode 2, or arming and disarming
the system from AWAY Mode is not permitted from the Keyswitch Zone.
Wiring Diagram for Keyswitch Zone
Wiring Diagram for Keyswitch Zone Using
Split EOL with Tamper
1
2
Z1 COM Z2
Z1 COM Z2
1
2
1 – EOL
2 – Keyswitch (Momentary/Toggle)
1 – EOL
2 – Keyswitch (Momentary/Toggle)
Table 9.1: Wiring Diagram for Keyswitch Zone