Fault Analysis Mode
Several system faults can be detected by the control panel. When any of these faults are
present, the FAULT indicator flashes and the codepad beeps once per minute.
To determine the type of fault:
Press and hold [5] until two beeps sound.
The STAY, AWAY, and FAULT indicators flash. One or more zone indicators (1 to 8) light to
indicate the type of fault that occurred.
To exit from Fault Analysis Mode:
Press [AWAY].
The STAY and AWAY indicators are extinguished and the system returns to the disarmed state.
Initiate a Modem Call
Holding down [6] until two beeps sound forces the control panel to dial the callback
telephone number programmed in Locations 159 to 174 in an attempt to connect to the
installer’s remote computer.
The remote computer must be running the A-Link Software and must be set to Waiting for an
Incoming Call. If no callback telephone number is programmed, holding down [6] has no
effect.
Reset Latching Outputs
Holding down [7] until two beeps sound resets any output that is programmed to remain on
after it is activated. The output must be programmed with a latching polarity.
Change the Codepad Buzzer Tone
Holding down [8] continuously changes the tone of the buzzer in the remote codepad. There
are 50 different tones from 1500 Hz to 5000 Hz. In an installation with multiple codepads, you
can set a different tone for each codepad.
To change the buzzer tone:
1. Press and hold [8] continuously. The tone of the buzzer increases in pitch.
2. Release [8] button when you hear the desired tone.
Notice!
Every time the system is powered down, you must reset each codepad to its individual tone
using this function.
On partitioned control panels, this hold-down function also indicates the area to which the
codepad belongs.
To determine the area to which the codepad belongs:
1. Press and hold [8] until two beeps sound. A zone indicator lights to show the area to which
the codepad belongs.
Zone 1 = Area 1 codepad
Zone 2 = Area 2 codepad
Zone1,2 = Common Codepad for both Area1 and Area2
If no zone indicator lights, the codepad is set up incorrectly or an incorrect codepad is used.
2. Press [AWAY] to exit from this mode.
7.4.8
7.4.9
7.4.10
7.4.11
Control Panel System Functions | en 79
Installation Guide 2014.07 | 00n | F01U298026