1 | Overview
3.2 | Install the module
2 | SDI2 address settings
You can congure the B450 using one of the methods described
in this section for your control panel type.
4 |
Conguration
4.1 |
Plug and play conguration
When installing under the following conditions, the B450 needs
no further conguration to communicate:
– AES Encryption is not required.
– Low signal delay can be no more than 200 sec.
4.2 |
Conguring with SDI2 control panels
An SDI2-compatible control panel automatically congures a
connected module.
1. Power off the compatible control panel.
2. Set the address switch to the correct address for the control
panel (SDI2 control panels use address 1 or 2).
3. Connect the module to the control panel bus and apply
power.
4. Program the control panel communication settings using
RPS or the keypad.
4.3 |
Conguring with SMS
The B450 supports conguration by SMS. You can send SMS via
mobile phone to the B450. For more information, refer to the
B450 Installation and Operation Guide.
Mount the B450 into the enclosure’s 3-hole mounting pattern
using the supplied mounting screws, and secure the antenna
onto the enclosure. Mount the B450 into the interior side of
the enclosure. Refer to Figure 3.2.
Callout ― Description
1 ― B450
2 ― Enclosure
3 ― Mounting screws (3)
4 ―
B44x plug-in cellular communicator antenna (routed through
any knock-out)
5 ― B44x plug-in cellular communicator antenna cable (connected
to the communication module)
Figure 3.3: Installing the module
3.3 | Wire to the control panel
When wiring a B450 to a control panel, you can use either the
module’s terminal strip labeled with PWR, A, B, and COM or
the module’s interconnect wiring connectors (wire included).
Interconnect wiring parallels the PWR, A, B, and COM terminals
on the terminal strip. Figure 1.1 indicates the location of both
the terminal strip and the interconnect connect connectors on
the module.
3 | Installation
Perform the following steps to install the B450.
2.1 | Set the B450 address
3.1 | Insert the module into the B450
Figure 3.3: Using SDI2 terminal strip or SDI2 interconnect cable
wiring (B5512 control panel shown).
Callout ― Description
1 ― SIM card
2 ― B44x cellular communication module (available separately)
3 ― B450
Figure 3.1.2: Inserting the communication module
Insert the communication module into the slot of the B450,
depending on your communication module (one with a SIM
card, or one without). Refer to Figure 3.1.2.
3
1
2
3
2
Callout ― Description
1 ― Control panel (B5512 shown)
2 ― B450 module
3 ― Terminal wiring strip
4 ―
Interconnect wiring (P/N: F01U079745) (included)
The B450 address switch determines the bus address of
the device. Set the address switch per the control panel
conguration. If multiple B450 devices reside on the same
system, each B450 module must have a unique system address,
and cannot share the same address value. Figure 2.1 shows the
address switch settings for address 01. Refer to Table 2.1 for
panel-specic settings.
The address switch determines the bus address for the
B450 module. The control panel requires the address for
communications. Use a slotted screwdriver to set the address
switch.
NOTICE!
The module reads the address switch setting only
during power up. If you change the switch after
you apply power to the module, you must cycle the
power to the module in order for the new setting to
be enabled.
Figure 2.1: Address switch set to address 1
Control Panels Switch
Position
Control
Panel
Address
Bus
Type
Function
USB or SMS
conguration setting
0 n/a Any Change
Conguration
B5512/B4512/B3512/
D9412GV4/D7412GV4/
D7212GV4/
Solution 2000/3000
1 1 SDI2 Automation, RPS,
or Reporting
D9412GV4/D7412GV4/
D7212GV4
Solution 2000/3000
2 2 SDI2 Automation, RPS,
or Reporting
D9412GV4/D7412GV4/
D7212GV4/D9412GV3/
D7412GV3/D7212GV3
D9412GV2/D7412GV2/
D7212GV2 v7.06+
4 88 SDI
1
RPS or Reporting
D9412GV4/D7412GV4/
D7212GV4
D9412GV3/D7412GV3/
D7212GV3
5 92 SDI
1
RPS or Reporting
AMAX 2000/2100/3000/
4000
CMS 6/8/40
Easy Series v3+
6 134 Option RPS or Reporting
FPD-7024 v1.03+ 9 250 Option RPS or Reporting
1
For D9412GV4/D7412GV4/D7212GV4 congurations, SDI2 bus connection
is the recommended conguration option, but SDI bus conguration is also
supported.
NOTICE!
Power up the B450 with the address switch set
to the desired bus. When ready to program using
SMS, turn the switch to position 0. When done
programming, turn the switch back. Failure to return
the address switch to the previous setting will result
in a troubled condition.
NOTICE!
Remove power to the control panel prior to wiring
a B450 module to the control panel using either the
terminal strip wiring or interconnect cable to wire to
the control panel. Do not use both.
NOTICE!
UL requires that for security installations, the B450
module be installed in a UL Listed enclosure with a
tamper.
The B450 Bus Communicator Interface Module (wired to a
compatible control panel) is a four-wire powered SDI2, SDI, or
Option bus device that provides two-way communication over
commercial cellular networks using a plug-in communicator.
The B450 on-board rotary switch determines the bus address of
the device. Conguration of the B450 is performed via USB or
SMS. On SDI2 control panels conguration can also be done on
the keypad or through Remote Programming Software (RPS).
Figure 1.1: Board overview
Callout ― Description
1 ― Tamper switch connector
2 ― Address switch
3 ―
MODE 2-pin connector (for future use)
4 ― Bus address label
5 ― USB connector
6 ― Heartbeat LED
7 ― RX LED (indicates packets received from the wireless network)
8 ― TX LED (indicates packets transmitted over the wireless net-
work)
9 ― Terminal strip (to control panel bus)
10 ―
Interconnect wiring connectors (to control panel bus or other
compatible modules)