DS7400XiV4-EXP | Reference Guide | 5.0 Programming the Control Panel EN | 87
Bosch Security Systems | 1/05| 4998154963B
Table 126: Output Functions, Program Addresses
1 to 3
Output
Function
1
Program
Address 1
Program
Address 2
(for Follow
Zone 1)
Program
Address 3
(for Follow
Zone 2)
1 2772 2773 2774
2 2775 2776 2777
3 2778 2779 2780
4 2781 2782 2783
5 2784 2785 2786
6 2787 2788 2789
7 2790 2791 2792
8 2793 2794 2795
9 2796 2797 2798
10 2799 2800 2801
11 2802 2803 2804
12 2805 2806 2807
13 2808 2809 2810
14 2811 2812 2813
15 2814 2815 2816
16 2817 2818 2819
17 2820 2821 2822
18 2823 2824 2825
19 2826 2827 2828
20 2829 2830 2831
21 2832 2833 2834
22 2835 2836 2837
23 2838 2839 2840
24 2841 2842 2843
1
See Section 5.9.38 Output Function Partition Assignment for information on assigning output functions to areas.
Data Digit 2 for Program Address 1 assigns the zone/control panel state to be followed. See Table 125 for Data
Digit 2 options.
For example, use the following steps to program Output Function 5 to follow Zones 2 and 3 when both zones are
shorted and the control panel is armed.
1. Enter “*5” (see Table 116) in Data Digit 1 of Program Address 1 (2784). See Table 126.
This option programs the output function to follow two zones in an input/output cross matrix. Outputs
assigned to this output function activate when both zones change state.
2. Enter “1” (see Table 125) in Data Digit 2 of Program Address 1 (2784).
This option programs the output function to activate when the zones it follows are shorted and the control
panel is armed.
3. Enter “0” in Data Digit 1 of Program Address 2 (2785), and “2” in Data Digit 2 of Program Address 2 to
assign this output function to Zone 2. The entries made in Program Address 2 are hex values (see Table 113).
4. Enter “0” in Data Digit 1 of Program Address 3 (2786), and “3” in Data Digit 2 of Program Address 3 to
assign this output function to Zone 3. The entries made in Program Address 3 are hex values (see Table 113).
Output Function 5 is now assigned to follow Zones 2 and 3. Any output assigned to Output Function 5 activates
when both Zones 2 and 3 are shorted, and the control panel is armed.