DS7400XiV4-EXP | Reference Guide | 4.0 Operating Guide EN | 21
Bosch Security Systems | 1/05| 4998154963B
Table 8: Authority Levels (continued)
Level
Number
Level
Name
Description
4 Temporary Valid only for a specified time
(the PIN expires on the
expiration date). It can arm and
disarm the system, but cannot
perform any other functions. If
this is done from a Master
keypad, the user must be in
Single Partition Mode. If access
is assigned to more than one
area, you must enter a
Temporary PIN expiration date
for all assigned areas (see
Changing the Expiration Date
for Temporary PINs below).
5 Duress When the system is disarmed
using the duress code, a silent
report is sent to the monitoring
service. The Duress code is
intended to be used when the
user is forced to disarm the
system.
6 Access
Code
When a PIN with an Access
Code is entered, any output
programmed for Access Output
(i.e. door strikes) pulses on for
10 seconds (works when the
system is armed or disarmed).
4.4.2 Programming PINs
PINs can only be added, changed, or removed in
Master Programming Mode; they are not
programmable from an RF (wireless) keypad.
Write down your entries before you enter the Master
Code Programming Mode and have them with you as
you begin programming. Make your entries promptly.
If a long delay occurs in your entries, the 3-beep error
tone sounds and exits you from the programming
mode.
It is recommended that all PIN programming
procedures be performed at a DS7447E/DS7447V2
keypad since this keypad provides visual prompts
throughout the programming sequence. No visual
clues are given from a DS7445i/DS7445V2 keypad.
When the programming sequence is successfully
completed, both the DS7447E/DS7447V2 and
DS7445i/DS7445V2 keypads signal the successful
completion with a long beep.
Perform the following procedure to add or change a
PIN:
If you are adding a temporary PIN, you
must enter the expiration date before
adding the temporary PIN.
1. Enter Master Programming Mode (press [Master
PIN][#][0]).
2. Enter a 0 for PIN Setup programming (press [0]).
3. Enter the User Number (enter a 3-digit number
from 001 to 200).
4. Enter the Authority Level (enter a number from 0
to 6).
5. Enter the Area(s) (Partitions) to which this user will
have access (press [1], [2], [3], [4], [5], [6], [7],
and/or [8] followed by [#]).
6. Enter the PIN (enter any 4- or 6-digit number; do
not press [#]).
7. Enter the PIN again followed by [#].
Perform the following procedure to set the
expiration date for an existing Temporary PIN:
1. Enter Master Programming Mode (press [Master
PIN][#][0]).
2. Enter a 3 for Date of Code Expiration Setup
programming (press [3]).
3. Enter the Expiration Month (press [0][1] for
January through [1][2] for December).
4. Enter the Expiration Day (press [0][1] through
[3][1]). The Temporary PIN expires at Midnight on the
day selected.
5. Enter the Year (enter the last two digits of the year
followed by [#]).
Entering the command sequence [Master
Code][#][0][3][#] causes the
DS7447E/DS7447V2 keypad to read back
the temporary code expiration date.
Perform the following procedure to remove a PIN:
1. Enter Master Programming Mode (press [Master
PIN][#][0]).
2. Enter a 0 for PIN Setup programming (press [0]).
3. Enter the User number of the PIN to be cancelled,
followed by [#] (enter a 3-digit number from 001
to 200, then press [#]).
User Number 001 cannot be disabled in
this manner.