DS7400XiV4-EXP | Reference Guide | 5.0 Programming the Control Panel EN | 73
Bosch Security Systems | 1/05| 4998154963B
5.9.33 Pager Delay Time
When using the Pager Dialing Format (selected in
Addresses 3156 and 3157; see Section 5.9.31 Phone
Number Format Programming), you can insert a delay
time after the phone number is dialed and before the
reports are sent to the pager system. This delay allows
greeting and instruction messages in the pager system.
This delay does not affect any other report formats.
The delay time is a two-digit number, programmed
across both data digits. For example, to set a delay time
of 5 seconds, make Data Digit 1 = 0 and Data Digit 2 =
5. The default delay time = 10 seconds (Data Digit 1 =
1 and Data Digit 2 = 0).
• Address: 4038
• Data Digit:
• Data Digit 1: ____ (default = 1)
• Data Digit 2: ____ (default = 0)
• Selections: 0 to 9
• Delay Time Range: 00 to 99 seconds
5.9.34 Programmer’s and Master Code
Programming (Addresses 7589 to 7592)
Programmer’s Code programming defines the
Programmer’s Code. This code is used to enter
Programming Mode from the keypads.
Although the DS7400Xi (Ver. 4+) Control
Panel is pre-programmed with 6-digit codes,
it is also shipped with a 4-digit PIN length
default. The default codes for the
Programmer’s Code and the Master Code
are 4-digits (9876 and 1234 respectively)
unless you reprogrammed for a 6-digit PIN
length.
Programmer’s Code
Enter the Programmer’s Code as six digits.
The Programmer’s Code cannot be the
same as any PIN number.
• Address: 7589
• Data Digit:
• Data Digit 1: ____ (default = 9)
• Data Digit 2: ____ (default = 8)
• Data Digit 3: ____ (default = 7)
• Data Digit 4: ____ (default = 6)
• Data Digit 5: ____ (default = 5)
• Data Digit 6: ____ (default = 4)
• Selections: 0 to 9
• Default: 987654
Master Code
Master Code programming defines what the Master
Code will be. This code is the highest authority level
for a PIN.
If the Master Code is lost, use this address to program
a new one. Otherwise, the Master Code Programming
Mode should be used to create PINs that have a Master
Code authority level.
Master Code for User Number 001 has its authority
fixed at Level 0. It will always have access to all areas.
User Numbers 002 through 200 must be
programmed from the Master Code
Programming Mode.
• Address: 7592
• Data Digit:
• Data Digit 1: ____ (default = 1)
• Data Digit 2: ____ (default = 2)
• Data Digit 3: ____ (default = 3)
• Data Digit 4: ____ (default = 4)
• Data Digit 5: ____ (default = 5)
• Data Digit 6: ____ (default = 6)
• Selections: 0 to 9
• Default: 123456
5.9.35 PIN Length Programming
PIN Length Programming defines the length of the
PINs that are assigned to each user. PINS can be
programmed to be 4 or 6 digits in length.
• Address: 3478
• Data Digit:
• Data Digit 1: ____ (see Table 101; default = 0)
• Data Digit 2: Must = 0
• Selections: 0 or 1
Table 101: Address 3478, Data Digit 1
Select Option Value
4-digit PINs
0
6-digit PINs 1