DS7400XiV4-EXP | Reference Guide | 7. Reference Materials EN | 110
Bosch Security Systems | 1/05| 4998154963B
If you are programming a single input device,
press [#] to contiune. The text keypad shows:
Sensor? Press 4
Contact? Press 6
Press [4] to enter sensor devices into the control
panel. Press [6] to enter contact devices into the
control panel.
The keypad sounds a single beep and scrolls to
the next zone if the device is properly entered.
If the zone is not programmed properly, the
keypad sounds a three-beep error tone.
e. Disconnect the device you just programmed
from the DS7430, and connect the next device.
Press [#] to continue programming.
24-hour zones will alarm when you exit the
programmer’s mode. Alarm reports for
these zones are sent if programmed. If you
do not want these reports sent, remove
power from the system now by
disconnecting the transformer and the red
battery lead. Do not reconnect power until
all zones are installed and connected to the
multiplex bus.
If there are no other multiplex zones to
program, the text keypad shows:
Mux Zone
Enter Zone
Press and hold [Reset/*] for two seconds to exit
the zone programmer’s mode. This returns you
to the programmer’s mode. Press and hold
[Reset/*] for two more seconds to exit the
programmer’s mode.
To disable or remove a multiplex zone, set the
program address’s data digits to 00.
7.2 Glossary
7.2.1 General Control Programming
Normal Arming: [PIN][On]: If programmed, arms the
entire system while allowing entry delays for entry/exit
zones.
Perimeter Instant Arming: [PIN][No Entry][Perimeter
Only]: If programmed, arms only the perimeter of the
system and does not allow entry delays for entry/exit
zones.
Perimeter Arming: [PIN][Perimeter Only]: If
programmed, arms only the perimeter of the system
while allowing entry delays for entry/exit zones.
Custom Arming: [PIN][#][4]: If programmed, allows
custom arming of the system and bypasses the zone
functions specified in data addresses 2725-2728.
Maximum Security Arming: [PIN][No Entry][On]: If
programmed, arms the entire system and does not
allow an entry delay for entry/exit zones.
General Authority by Area: A general (level 2)
authority can be programmed to have arm-only
authority; arm and bypass authority; arm and disarm
authority; or arm, disarm, and bypass authority by
area. This is done at addresses 3421-3424.
• Arm-only access by area allows someone with a
General Authority to arm zones in an area he can
not disarm.
• This level can still be used to arm, disarm, and
bypass zones in the other areas that it has access
to.
Closing Ring-Back: If programmed, the keypad
sounders and Bell will activate for 2 seconds after the
system is armed and the closing report is successfully
sent. This requires Closing Ring-Back and Closing
Report to be programmed.
• If a closing report is not programmed, the control
panel will test for a dial tone when the system is
armed. If the test passes, the system will arm
normally. If the test fails, the system will arm, but
will indicate a trouble condition.
• The DS7447E/DS7447V2 keypad will display
"Communication Err" after [#][8][7] is entered.
Siren on Comm. Fail for Silent Zone: If
programmed, a silent zone will sound the alarm
outputs if the zone is in an alarm condition and the
system fails to communicate with the central station.
Restore when Sounders Silence: If programmed, a
zone sends a restoral report and is ready to activate
again only after the burglary bell cut-off time expires
or the bells are silenced.
• The zone can alarm multiple times per armed
period.
Restore when Zone Restores: If programmed, a zone
sends a restoral report and is ready to activate again as
soon as it physically restores.
• This zone can alarm multiple times per armed
period.
Restore when System Disarms: If programmed, a
zone sends a restoral report when the system is
disarmed.
• It can only alarm once per armed period.