10-98 Handling, Diagnostic and Service Functions MPH-02, MPB-02, MPD-02
DOK-INDRV*-MP*-02VRS**-FK01-EN-P
Supported Services and Subservices
SIS
service
Description Subservices Subservice description Notes
0x01 reading SIS version subservice is implemented but
not active
0x02 reading firmware version supplies content of S-0-0030
0x03 reading controller type supplies content of S-0-0140
0x00 node identification
0x04 reading supported baud
rates
9600 baud, 19200 baud, 38400
baud, 57600 baud, 115200
baud
0x01 data transmission
canceled
none
0x90 shutdown switches drive firmware to the
loading mode
0x91 reboot causes restart
0x92 read flash reads content of the flash
0x93 find header supplies header address of the
first IBF module
0x94 erase flash deletes content of the flash
0x96 program flash programs content of the flash
0x97 build checksum supplies CRC32 checksum of
the indicated IBF module
0x02 flash operations
0x9F error reset in the slave clears error in loading mode
0x01 determining TrS initializes max. reaction time in
the slave
0x02 determining TzA initializes max. character
interval on the bus
0x03 determining Tmas subservice is implemented but
not active
0x07 determining the baud rate initializes the baud rate of the
serial transmission
0x08 time-controlled baud rate
test
allows temporary change of the
baud rate
0x03 initialization of the
SIS communication
0xFF accepting the determined
values
activates the values initialized
with the subservices 0x01,
0x02 and 0x07
0x10 reading parameter none 0x10 = 0x80
0x11 reading list segment none segment information in byte
0x1E writing list segment none segment information in byte
0x1F writing parameter none 0x1F = 0x8F
0x80 reading parameter none 0x80 = 0x10
0x81 reading list segment none segment information in word
0x8E writing list segment none segment information in word
0x8F writing parameter none 0x8F = 0x1F
Fig. 10-61: Supported services and subservices
Zobrazit stránku 679
1 2 ... 675 676 677 678 679 680 681 682 683 684 685 ... 727 728

Komentáře k této Příručce

Žádné komentáře

Bauknecht BIK9 PP8TS2 PT Handbücher

Bedienungsanleitungen und Benutzerhandbücher für Messen, Testen & Steuern Bauknecht BIK9 PP8TS2 PT.
Wir stellen 2 PDF-Handbücher Bauknecht BIK9 PP8TS2 PT zum kostenlosen herunterladen nach Dokumenttypen zur Verfügung Betriebsanweisung






Weitere Produkte und Handbücher für Messen, Testen & Steuern Bauknecht

Modelle Dokumententyp
BIK9 MH8TS3 PT Betriebsanweisung   Bauknecht BIK9 MH8TS3 PT Setup and user guide [en] , 12 Seiten
BIK7 MP8TS PT Betriebsanweisung   Bauknecht BIK7 MP8TS PT Setup and user guide, 12 Seiten
BIK9 MP8TS3 PT Betriebsanweisung   Bauknecht BIK9 MP8TS3 PT Setup and user guide, 12 Seiten