MPH-02, MPB-02, MPD-02 Motor, Mechanical Axis System, Measuring Systems 5-35
DOK-INDRV*-MP*-02VRS**-FK01-EN-P
Required type plate data:
1. Rated current
rms value of the electric current in the motor feed wire (motor
phase) at rated load
2. Rated voltage
rms value of the voltage between the motor terminal connectors at
rated load
3. Rated frequency
frequency of the feeding, sinusoidal electric voltage
4. Rated speed
speed of motor output shaft at rated load
5. 3RZHUIDFWRUFRV
power factor at rated load
6. Rated power
power that can be continuously delivered at rated load
Note: "Rated load" means load of the motor output shaft with rated
torque when feeding the motor with rated voltage and rated
frequency.
The power at the output shaft is the rated power.
Condition:
The rated load point mustnt be in the field weakening range!
With the command P-0-4033, C3200 Command Calculate data for
asynchronous motor the parameter values listed below are calculated
from the type plate data of the asynchronous motor entered in list
parameter P-0-4032.
Internally calculated motor parameters for asynchronous motors with
"open-loop" operation and "closed-loop" operation:
S-0-0106, Current loop proportional gain 1
S-0-0107, Current loop integral action time 1
S-0-0109, Motor peak current
S-0-0111, Motor current at standstill
P-0-0051, Torque/force constant
P-0-0528, Flux control loop proportional gain
P-0-0529, Scaling of stall current limit
P-0-0532, Premagnetization factor
P-0-0533, Voltage loop proportional gain
P-0-0534, Voltage loop integral action time
P-0-0535, Motor voltage at no load
P-0-0536, Motor voltage max.
P-0-4004, Magnetizing current
P-0-4036, Rated motor speed
P-0-4039, Stator leakage inductance
P-0-4040, Rotor leakage inductance
P-0-4041, Motor magnetizing inductance
P-0-4042, Characteristic of motor magnetizing inductance
P-0-4043, Rotor time constant
P-0-4048, Stator resistance
Internally Calculated Motor