7-90 Operating Modes MPH-02, MPB-02, MPD-02
DOK-INDRV*-MP*-02VRS**-FK01-EN-P
The figure below illustrates the relative synchronization to a virtual master
axis, the master axis having a velocity 0 when the operating mode is
activated.
DK000042v01_en.fh7
t
t
0
0
t
master axis
velocity
0
velocity
of slave axis
operating mode
activated
1
t
0
1
0
P-0-0142
synchronization
completed
(P-0-0152, bit 0)
Fig. 7-69: Example: relative synchronization in running operation
When the operating mode is activated, the master axis moves at
constant velocity.
Based on its current position the slave axis accelerates to the
synchronous velocity. While doing this the synchronization
acceleration (P-0-0142) is effective.
Upon reaching the synchronous velocity the bits for "synchronization
completed" (P-0-0152, Bit 0 = 1) and "slave axis has been
synchronized" (P-0-0089, bit 8 = 1) are output.
Relative Synchronization in
Running Operation