American Dynamics 8 Channel IP Encoder
18-1
American Dynamics 8 Channel IP Encoder
Supported Key Functions
• Video Streaming – Single and Dual
• Video Codec – MJPEG, MPEG4 and H.264
• Audio Streaming – Audio Codec’s are AAC, G.711 ulaw and G.711 alaw
• PTZ – Applies to analog cameras that have mechanical Pan, Tilt, and Optical Zoom
• Dry Contact Events – Camera is polled for dry contact event at 100ms interval
• Reset to Factory Defaults
• Query Device
• Reboot Device
• Bitrate control now supported – VBR provides a quality drop down range and CBR provides a
bitrate value option.
Required Ports
• Port 80 is for HTTP
• Port 554 is for RTSP
Default Username & Password
• Username: user
• Password: user617
Limitations
• Changing the video source requires a reboot of the encoder. During the reboot, the device will
not respond.
• Changing the interlacing parameter requires a reboot of the encoder. During the reboot, the
device will not respond.
• Changing streaming parameters like bit-rate, quality, frame-rate, key frame interval and others
would require the stream to be restarted, hence a small glitch in play out might be observed
during this time.
• Consecutive audio channel pairs should be configured with same codec otherwise RTSP will
send a 500 message. Pairing as {PCMU,PCMA},AAC.
• Due to a limitation in the Encoder firmware, the QCIF video stream uses the 172x112 resolution.
• Pattern cancel feature is not support in consistent manner. If “Pattern Cancel” is selected via
victor unified client, recorded pattern will be saved, overwriting the existing pattern.