If there are two or more zones programmed as delay zones and both are triggered,
the follower zone will follow the first triggered delay zone
3. STAY ARM: same as the delay zone.
6 - Interior Follower
The interior follower zone will perform as below:
1. Disarm: same as the Instant Zone disarm status
2. AWAY Arm: same as the Follower Zone AWAY Arm status
3. STAY Arm:
This zone will be ignored and performed as disarm.
Refer to Section Keypad Indicators, page 20 to see how the zone is displayed during
exit time.
7 - 24 Hour Zone
The 24 Hour zone will perform as below:
1. Disarm:
Zone normal - no Alarm / no report
Zone triggered - Alarm / report
2. AWAY Arm:
Zone normal - no Alarm / no report
Zone triggered - Alarm / report
Zone triggered - during exit time - Alarm / report
Zone triggered - during entry time - Alarm / report
3. STAY Arm: Same as AWAY Arm performance.
A 24 Hour zone does not send a restore report until the zone is restored.
8 - Tamper Zone
The Tamper zone will perform as below:
1. Disarm:
Zone normal - no Alarm / no report
Zone triggered - Alarm / report
2. AWAY Arm:
Zone normal - no Alarm / no report
Zone triggered - Alarm / report
Zone triggered - during exit time - Alarm / report
Zone triggered - during entry time - Alarm / report
3. STAY Arm: Same as AWAY Arm performance.
A Tamper zone does not send a restore report until the zone is restored.
9 - Fire Zone
The Fire zone will perform as below:
1. Disarm:
Zone normal - no Alarm / no report
Zone triggered - Alarm / report
2. AWAY Arm:
Zone normal - no Alarm / no report
Zone triggered - Alarm / report
Zone triggered - during exit time - Alarm / report
Zone triggered - during entry time - Alarm / report
3. STAY Arm: Same as AWAY Arm performance.