Zone Area, Zone Functions and Module Selection
Zone
No
Area Selection
Address
Default Zone Function
Selection
Address
Default Module
Selection
Address
Default
1 0678 - 0679 01 0806 3 0870 0
2 0680 - 0681 01 0807 1 0871 0
3 0682 - 0683 01 0808 1 0872 0
4 0684 - 0685 01 0809 1 0873 0
5 0686 - 0687 01 0810 1 0874 0
6 0688 - 0689 01 0811 1 0875 0
7 0690 - 0691 01 0812 1 0876 0
8 0692 - 0693 01 0813 1 0877 0
9 0694 - 0695 01 0814 0 0878 0
10 0696 - 0697 01 0815 0 0879 0
11 0698 - 0699 01 0816 0 0880 0
12 0700 - 0701 01 0817 0 0881 0
13 0702 - 0703 01 0818 0 0882 0
14 0704 - 0705 01 0819 0 0883 0
15 0706 - 0707 01 0820 0 0884 0
16 0708 - 0709 01 0821 0 0885 0
Value Range:
00 = zone not used,
1 - 16 = Area 1- 16
Value Range:0 –15. See
Section Zone Functions
0 = On-board zone
1 = Keypad Zone
2 = DX2010 Zone
3 = RF Device
15 = not used
Notice!
Zones may be indicated on keypads with a number that are different from zone number used
for programming and hardware input.
Example:
In a one area system keypad zone number 17 should be indicated as Zone number 16 (e.g.
visible on 16 zone LED keypad). After disabling zone 16 * (or another one in range 1 to 16)
zone number 17 is indicated on keypad as number 16.
* change Area Selection to 00 = zone not used
Notice!
When a zone is assigned to RF Device (3), then the dedicated On-board zone is not available.