To program the IP Address and port:
Use no punctuation in IP address. If any unit of IP address is less than 3 digits, use 0 to fulfill
the data in the higher bits. The remaining 5 digits will program the port. Port number ranges
from 0-65535. Any port is less than 5 digits, use 0 to fulfil the data.
Example
To program the IP Address 10.16.1.222:80 as the IP Address of Receiver 1, enter the following
sequence into Address 000 - 016:
[0 1 0 0 1 6 0 0 1 2 2 2 0 0 0 8 0]
Notice!
Programming option anti-replay, acknowledge wait time and pulse interval time are only used
in Conettix IP.
Telephone number for Receiver 1 - 4/IP Address and Port
When the corresponding data format for above programming address is a network
communication format, it is explained as an IP Address and Port. For a non network format, it
is explained as telephone number.
When the control panel transmits a report, it dials the telephone number/IP Address to
contact the monitoring station. If the call is successful, the relevant information is transmitted
and the dialer returns to Standby Mode.
Contact your monitoring station for the correct telephone number/IP Address before you
program these addresses.
Receiver Subscriber ID Number
Receiver 1 - 4 Subscriber ID Number
The Subscriber ID Number is transmitted to identify the calling control panel. Enter the
Subscriber ID Number in the six addresses provided for each destination. If a Subscriber ID
Number is less than 6 digits, use 0 to full fill the data in the higher bits.
Example
Program Subscriber ID Number as 4729 in six addresses: [0 0 4 7 2 9]
Receiver Transmission Format
Transmission Format
Receiver 1 - 4 Transmission Format
You can select the transmission format with Address options to specify how to transmit the
information to the base station receiver. If Contact ID or SIA format is selected, the
information is transmitted by telephone line; if Bosch Network is selected, then it is
connected with B426/DX4020 or ITS-DX4020G GPRS. Transmission format is defaulted as
Contact ID.
Transmission Formats (Contact ID, SIA, Conettix IP)
The AMAX panel 4000 / AMAX panel 4000 EN provides three kinds of transmission formats,
Contact ID, SIA and Conettix IP format for its dialing and communication features. Program
the transmission format for Receiver 1, 2, 3 and 4 separately in Address 023, Address 053,
Address 083 and Address 113 (refer to Transmission Format). The control panel is set at the
factory to report in the Contact ID Format.
7.1.2
7.1.3
AMAX panel 4000 / AMAX panel 4000
EN
Settings | en 33
Bosch Sicherheitsysteme GmbH Installation Guide 2013.07 | 03 | F.01U.267.112