System Status Report (Zone fail, comm. fail, telephone
line fail, AC fail, low batterie...etc.)
0124 6
EN=1/5/6/7
Keypad Panic Alarm Report 0125 0
Keypad Fire Alarm Report 0126 0
Keypad Medical Alarm Report 0127 0
Automatic Test Report 0128 6
EN=1/5/6/7
0 = No report, 1 = Receiver 1, 2 = Receiver 2, 3 = Receiver 3, 4 = Receiver 4, 5 = Receiver
1,2,3 and 4, 6 = Receiver 1 (2,3 and 4 for backup), 7 = Receiver 1 (2 for backup) and receiver
3 (4 for backup)
Notice!
When the Transmission Format for Receiver in the receiver programming is set to 0 (not
used), i.e., setting the report option as sending report to a receiver, then the alarm control
panel will actually not send any report.
Automatic Test Report
Address 0129 - 0134 Address Default
Test Report Time: Interval
00 = Do not use timing report , 01 - 99 = 1 - 99 hours
0129 - 0130 24
VDS-A
EN=1-24
Report Time: Hour
00 - 23 = 0 - 23 hours, Others = Do not use real-time
report
0131 - 0132 99
Report Time: Minute
00 - 59 = 0 - 59 minutes, Others = Do not use real-time
report
0133 - 0134 99
Report Expiry Time
Address 0135 - 0137
Address Default
000 = No time limit, 001 - 255 = 1 - 255 minutes 0135 - 0137 000
VDS-A
EN=000
Installer Access Until Next Arming
Address 0138
Address Default
0 = disabled, 1 = enabled 0138 0
VDS-A=1
Force Arm When System Is In Trouble Condition
Address 0139
Address Default
0 = disabled, 1 = enabled 139 1
VDS-A EN=0
AMAX panel 4000 / AMAX panel 4000
EN
Programming | en 109
Bosch Sicherheitsysteme GmbH Installation Guide 2013.07 | 03 | F.01U.267.112