Panel PCB: – Quiescent current maximum 100mA
Battery: – 12V/7 Ah, lead acid rechargeable
– 12V/17Ah, lead acid rechargeable
– Low battery condition is below 11,0 VDC
– Minimum battery condition is 10,8VDC
Certification: – EN 50131-3 Grade-3 Environmental Class-II
Keypads:
IUI-AMAX4-TEXT (LCD Text Keypad)
Relative Humidity: – 10%-95%
Operating Temperature: – -10°C - +55°C
Input Voltage range: – 10.8VDC - 13.8VDC
Current Consumption: – standby 31mA
– maximum 100mA
Cable requirements: – four wire, AWG18 or AWG22
– maximum length 200m (Panel to last KP)
– maximum BUS 1 length 700m (max 14 devices, max 8
KPs)
– maximum BUS 2 length 700m (max 14 devices, max 8
KPs)
EN type: – EN = B, IK = 06, IP = 30
Certification: – EN 50131-3 Grade-3 Environmental Class-II
IUI-AMAX3-LED16 (16 Zone LED Keypad)
Relative Humidity: – 10%-95%
Operating Temperature: – -10°C - +55°C
Input Voltage range: – 10.8VDC - 13.8VDC
Current Consumption: – standby 31mA
– maximum 60mA
Cable requirements: – four wire, AWG18 or AWG22
– maximum length 200m (Panel to last KP)
– maximum BUS 1 length 700m (max 14 devices, 8 KPs)
– maximum BUS 2 length 700m (max 14 devices, 8 KPs)
EN type: – EN = B, IK = 06, IP = 30
Certification: – EN 50131-3 Grade-3 Environmental Class-II
IUI-AMAX3-LED8 (8 Zone LED Keypad)
Relative Humidity: – 10%-95%
Operating Temperature: – -10°C - +55°C
Input Voltage range: – 12V normal
AMAX panel 4000 / AMAX panel 4000
EN
Technical Data | en 173
Bosch Sicherheitsysteme GmbH Installation Guide 2013.07 | 03 | F.01U.267.112