room. It is required for the successful vendor
to integrate, and maintain, the existing
Radionics systems with the newly provided and
installed systems. The existing Radionics
control panel must be programmed to send a
contact closure when the system is activated.
Contact closure will be used to index the
Integral system to allow building entrance only
to personnel that have both an access card and
disarm code. Vendor is responsible for all
costs, coordination and equipment related to
integrating the existing Radionics systems into
the Integral system. Existing Radionics systems
are serviced and monitored by AAA Security
Systems, 860-675-0427.
E. Systems integration will also include the
audio/video intercom system. The audio/video
intercom system shall have a door release
function that will allow for selective door
opening from the internal master station. Upon
arrival, a visitor will be required to activate
the call button on the door station that then
opens a communication path between the door
station and the internal master. Once
communication is established, the person at the
internal master station can activate the door
release button thereby releasing the electric
strike and allowing entry into the building.
F. Integrated CCTV systems with digital video
recording shall also be installed. Camera
locations can be found on the project drawings.
The video images supplied by these cameras shall
be digitally recorded, and stored for a 30-day
period, to allow viewing of both stored and live
streaming video from any authorized computer on
the network.
G. Remote access is to be provided and installed at
the Board of Education Facilities office and the
Police Department Dispatch office. PC Anywhere
software is currently installed in these
locations and contractor is responsible that the
remote access functions are extended to the
Chippens Hill Middle School. Integral Tech Remote
View, or equivalent, shall be provided and
Komentáře k této Příručce