directly from the back up magnetic media
without the need to interrupt normal on-
line activity of the ACAM system.
D. Historical Reports.
a. The system shall be capable of producing the
following reports, based on logged historical
events over a specified date and time period,
both individually and in any combination.
1) Report of valid access for a selected
cardholder, selected card reader, on
selected area(s).
2) Report of rejected access attempts for a
selected cardholder, selected card
reader, and selected alarm activation’s
for a selected alarm point, on selected
area(s).
3) Report of alarm acknowledgments for a
selected alarm or group of alarms.
4) Report of operator entered comments in
conjunction with alarm acknowledgments.
5) Report of manual operator override
commands such as performed alarm point
masking/unmasking, manual card reader
door locking and unlocking, and manual
auxiliary relay activate/deactivate.
6) Report of automatic time controlled
system commands such as automatic
masking/unmasking, and automatic door
lock/unlocks.
7) In addition, the system shall offer the
user the option of directing the
historical reports to a client
workstation color monitor for display or
to the report printer.
E. Cardholder Reports.
a. The system shall be capable of producing
lists of selected cardholder data records on
a client workstation color monitor and/or a
report printer. The system shall allow the
user to sort by card number, cardholder name
or other fields.