D7212GV2 | Program Entry Guide | 2.0 GV2MAIN EN | 17
Bosch Security Systems, Inc. | 1/08 | F01U003804-04
Table 10: Test Reports
Report Selections Report Description
R# S: Alarm
1
Yes, No
Status Alarm
R# S: Trouble
1
Yes, No
Status Trouble
R# S:
Supervised
2
Yes, No
Status Supervised
R# Status
Report
Yes, No
Status
R# S: Open
1
Yes, No
Status Open
R# S: Close
1
Yes, No
Status Close
R# Test Report
Yes, No
Test
R# S: Perim
Inst
1
Yes, No
Status Perimeter
Instant Arm
R# S: Perim
Delay
1
Yes, No
Status Perimeter
Delay Arm
R# S: Fire
Supv
2
Yes, No
Status Fire
Supervision
R# S: Fire
Alarm
3
Yes, No
Status Fire Alarm
Report
R# S: Fire Trbl
2
Yes, No
Status Fire Trouble
R# S: Msng
Fire
2
Yes, No
Status Fire Missing
R# S:
MsngBurgTr
2
Yes, No
Status Burg
Missing Trouble
R# S:
MsngBurgAl
2
Yes, No
Status Burg
Missing Alarm
R# S:
FireSpMsng
2
Yes, No
Status Fire
Supervision Missing
R# S:
SuperMsng
2
Yes, No
Status Non-fire
Supervision Missing
R# S:
DrLeftOpen
4
Yes, No
Status Door Left
Open
1
Information about this condition is sent with a Status
Report.
2
Information about this condition is sent as S: Trouble
Event with a Status Report.
3
Information about this condition is sent as S: Alarm
Event with a Status Report.
4
This event is not transmitted for the D7212GV2. Use
only the default setting.
Diag Reports
Selecting Yes enables sending a report when the event
occurs. If the off-normal state of any events indicated
by footnote 1 in Table 11 still exists, the events report
when a Test Report is enabled and
Expanded Test
Rpt
is programmed Yes. Refer to the
Test Reports
sub-prompt in Section 2.3.8 Dialing Attempts on page 13.
Table 11: Diagnostic Reports
Report Selections Report
Description
R# SDI Dev Fail
1
Yes, No
SDI device
failure
R# SDI Dev Restl
Yes, No
Restoral of SDI
device failure
R# Watchdog Rset
Yes, No
Watchdog
Reset Event
R# ParaChksmFail
Yes, No
Parameter
checksum
failure
R# Reboot
Yes, No
Reboot Event
R# Ph Line Fail
1
Yes, No
Failure of phone
line
R# Ph Line Rstl
Yes, No
Restoral of
phone line after
failure
R# AC Fail
1
Yes, No
Failure of AC
power to control
panel
R# AC Restorl
Yes, No
Restoral of AC
power to control
panel after
failure
R# Batt Missing
1
Yes, No
Battery Missing
Detection Event
R# Battery Low
1
Yes, No
Low battery
power
R# Battery Rstl
Yes, No
Restoral of
battery power to
control panel
after Missing or
Low Event
R# Rt Comm Fail
1, 2
Yes, No
Failure to send
report to
specific route
R# Rt Comm Rstl
Yes, No
Restoral of
communication
to specific route
after a failure