D7212GV2 | Program Entry Guide | 5.0 RADXSKED EN | 102
Bosch Security Systems, Inc. | 1/08 | F01U003804-04
00:00 is midnight, 23:59 is 11:59 PM. Make entries
using a 24-hour clock (for example, 7:00 AM is
entered as 07:00, 2:45 PM is entered as 14:45).
Reboot the control panel to activate today’s window.
The window needs to activate on the same day you
program it.
W# Close Window Start
Default: 00: 00
Selection: HH:MM (hours and minutes)
Enter the time that you want the control panel to start
the Closing Window. The window goes into effect at
the beginning of the minute.
00:00 is midnight, 23:59 is 11:59 PM. Make entries
using a 24-hour clock (for example, 7:00 AM is
entered as 07:00, 2:45 PM is entered as 14:45).
This program item is one of three required to create a
Closing Window. To program a Closing Window,
Close Early Begin and Close Window Stop must also
be programmed.
If the area is not armed when the Close Window Start
time comes, a warning tone sounds and PLEASE
CLOSE NOW appears at the keypad. To temporarily
silence the tone, press the [ESC] key on the keypad.
The warning tone restarts in 10 min if the area is not
armed.
Refer to the
W# Close Early Begin
prompt in this
section for explanations of report features.
W# Close Window Stop
Default: 00: 00
Selection: HH:MM (hours and minutes)
Enter the time that you want the control panel to end
the Closing Window. The window stops at the end of
the minute.
00:00 is midnight, 23:59 is 11:59 PM. Make entries
using a 24-hour clock (for example, 7:00 AM is
entered as 07:00, 2:45 PM is entered as 14:45).
This program item is one of three required to create a
Closing Window. To program a Closing Window,
Close Early Begin and Close Window Start must also
be programmed.
If the area is not armed by the time the Close Window
Stop time expires, the control panel generates a Fail to
Close Report if enabled in Fail To Close.
Closing Reports generated between the Close Window
Start time and Close Window Stop time can be
suppressed by programming
Disable O/C in
Window
as Yes. Refer to the
W# Close Early Begin
prompt for other explanations of report features.
Do not use a time of 23:59 as a window stop time
unless the window continues on the next day at 00:00.
Fail to Close Reports are not sent, and the Auto Close
feature does not work for windows that stop at 23:59.
Do not program a single window to cross the midnight
boundary. The window stop time must be later than
the window start time. To program a window that
effectively crosses the midnight boundary, you must
program two windows.
For example, to program windows for an area that
closes between 11:30 PM and 12:30 AM, five days a
week, use two windows as shown in Table 33.
Table 33: Programming Example: Using Two Closing Windows to Cross the Midnight Boundary
Open Close
W# Day of Week
Early
Begin
Start Stop
Early
Begin
Start Stop
eXcept
On
Holiday
Holiday
Index Area(s)
1
S M T W T F S
22 : 00 23 : 30 23 : 59
Yes No
1 2 3 4
1 2 3 4 5 6 7 8
2
S M
T W T F S
00 : 00 00 : 00 00 : 30
Yes No
1 2 3 4
1 2 3 4 5 6 7 8