DCN Next Generation Open Interface Release 2.4 Text Status Display
en | 215
Bosch Communications Systems | 2007 February | SRS_LDINF | Du080902
APPENDIX B. ERROR CODES
Responses returned upon a remote function request contain an error field (‘wError’). In this
appendix an overview is given of the possible errors and their values.
Text & Status Display Error code Value (hex.)
Explanation
LD_E_NOERROR
0 (0x00)
The execution of the remote function was successful.
LD_E_INCONTROL_THIS_CHANNEL
3074 (0xC02)
The LD application is already controlled by this remote controller
(on the same channel). Probably the LD_C_START_LD_APP is
called for the second time.
LD_E_INCONTROL_OTHER_CHANNEL
3075 (0xC03)
The LD application is already controlled by another remote
controller (on another channel).
LD_E_UNKNOWN_DISPLAY
3076 (0xC04)
The display id passed in the remote function is unknown (i.e. not in
the range LD_C_DISPLAY_ONE – LD_C_DISPLAY_FOUR).
LD_E_WRONG_PARAMETER
3077 (0xC05)
A parameter passed in the remote function has an invalid value.
LD_E_LINES_OVERFLOW
3078 (0xC06)
The total number of lines configured for MM display information
exceeds the maximum of
LD_C_MAX_NUMBER_OF_DISPLAY_LINES (i.e. the number of
speaker lines added tot the number of request-to-speak lines
exceeds LD_C_MAX_NUMBER_OF_DISPLAY_LINES).
LD_E_APP_NOT_STARTED
3079 (0xC07)
Indicates that no remote controller has taken over the LD
application control from the CCU (and therefore the remote
controller is not allowed to call the remote function).