DCN Next Generation Open Interface Release 2.4 Simultaneous Interpretation
en | 152
Bosch Communications Systems | 2007 February | SRS_ININF | Du030905
wNrOfInstances The value of the update use count for the IN application at the
end of the function handling. It contains the number of times a
remote controller has connected over the same communication
medium. E.g. the first time the IN_C_START_MON_IN function
is called, it contains the value 1. Note that calling
IN_C_START_IN_APP also increases this update use count.
Error codes returned
IN_E_NOERROR
Update notifications
IN_C_CCU_CONFIG
IN_C_CHAN_STATUS
IN_C_LANGUAGE_LIST
IN_C_FLASHING_MIC_ON
IN_C_SPEAKSLOWLY_SIGN
IN_C_HELP_SIGN
Related functions
IN_C_STOP_MON_IN
3.2.5 IN_C_STOP_MON_IN
Purpose
Function to stop monitoring the behavior of the Simultaneous Interpretation application.
Parameter structure for the function
The function has no additional parameters.
Response structure from the function
The function returns the following structure:
WORD wNrOfInstances;
where:
wNrOfInstances The value of the update use count for the IN application at the
end of the function handling. It contains the number of times a
remote controller is connected over the same communication
medium. E.g. when there is only one connection registered for
the IN application prior to calling the IN_C_STOP_MON_IN
function, the value of wNrOfInstances will be 0 when the
function returns. Note that calling IN_C_STOP_IN_APP will
also decrease this update use count.
Error codes returned
IN_E_NOERROR
Related functions
IN_C_START_MON_IN
3.2.6 IN_C_DESK_UPDATE
Purpose
This function updates an interpreter desk configuration in the CCU with a new configuration
from the remote controller. It only changes data for one desk. If a microphone is on, it will be
turned off first. The desk gets a download and will be brought up in its default state. The
default B out channel is the lowest channel enabled. If no interpreter with the specified
booth/desk combination can be found an error is returned. An interpreter unit that is being
installed when this function is called will leave its installation menu.
Parameter structure for the function
The function requires the following structure as parameter: