wLSN | Reference Guide | 5.0 wLSN PIR and Dual Motion Detectors
28 Bosch Security Systems, Inc. | 3/07 | F01U009440-01
5.2 Walk Testing
To maximize battery life, the LED elements do not activate
unless the unit is in the Walk Test mode.
Perform a Walk Test to determine the boundaries of the coverage
area. Walk Test mode can be started from the:
• Control Panel: Enter the appropriate command sequence at
the control panel to start the Walk Test mode (refer to the
control panel’s documentation).
• Detector: Slide open and then close the detector cover to start
a 90-sec Walk Test mode. Walk Test mode is now active.
Motion detected within the detector’s coverage area activates the
red LED, sends a signal to the control panel, and restarts a 90-sec
timer. If there is no motion for 80 sec, the red LED flashes for the
last 10 sec to indicate Walk Test mode is ending. Motion detected
during the last 10 sec restarts Walk Test mode.
1. Start at the pattern’s expected boundary and walk across the
pattern moving closer to the detector at each pass while
observing the LED (Figure 6). Refer to Table 11 on page 29
for LED indications.
Figure 6: Walk Test
During Walk Test mode for the wLSN Dual Motion
Detector, a motion alarm signal is sent to the control panel
only when the red LED flashes (Table 11). It is normal to
see a brief green or yellow flash before a red alarm
indication when walk testing the Dual Motion Detector.