D9412GV2/D7412GV2
D9412GV2/D7412GV2 Release Notes for Version 7.05
© 2007 Bosch Security Systems, Inc. Page 9 F01U003637-02
• The battery backed-up RAM now has a Super-
Cap installed. The Super-Cap maintains power for
up to 30 minutes to the control panel’s memory
when replacing the lithium battery. In earlier G
Series Control Panels, if the coin battery was
removed and the control panel was powered
down, all configuration was lost. This
enhancement allows the control panel to retain its
configuration during necessary battery
replacement.
• The D928 line monitor senses trouble if voltage
on the line falls to 5.0 to 7.0 VDC without a
corresponding value of at least 13 mA of current.
• The GV2 Series Control Panels now have
integrated watchdog supervision. The D928 Dual
Phone Line Switcher is no longer needed, but is
still fully supported.
5.0 Known Issues
• When a faulted local point is force armed, the
central station receives a Forced Close Report for
that point. In the current version, the control
panel does not send Forced Close Reports for
faulted local points.
In addition, if both a local and a non-local point
are faulted and force armed, the control panel
does not send Forced Armed, Forced Point, or
Forced Close Reports for the non-local point.
A point is local if it is configured as:
Local While Armed = Yes
Local While Disarmed = Yes
• On the D1260 and D1260B Keypads, View Area
Status does not show the default area status text.
Instead, it shows the custom area status text
programmed in the program record sheet.
• On the D1260 and D1260B Keypads, the
Setup?> menu under the Service Menu
(99 + ENTER), is currently unavailable. The
default values for the Bright Dim mode are
Bright = 10 and Dim = 3.
• When numerous devices are connected to the SDI
bus, the performance of automation applications
and keypads is slower than in previous G Series
control panels. The performance will be improved
in a future revision.
• When a Status Report is sent through Netcom to a
central station receiver or is printed out through a
D9131A printer module, some of the details are
erroneously omitted.
• On the D1260 and D1260B Keypads, when the
Sensor Reset command (COMMAND 47) is
executed, Call for Service appears
erroneously on the display for a brief time. This
effect also occurs when the control panel reboots.
• The Anti-Replay feature is intended for use with
only one IP reporting path. Do not set
Enable
Anti-Replay
to Yes if two or more IP reporting
paths are used.
• The Time Sync feature used to update the control
panel’s internal calendar clock automatically can
cause intermittent erroneous skipping or
duplication of skeds. The Time Sync feature uses
an enhanced communication path and can be
enabled or disabled only at the D6600 Receiver.
• Change the Service Passcode (User ID 0) factory
default value when the ANSI SIA CP-01 required
Passcode Length parameter is 4 or greater.
• The RPS call-back feature using the network is not
available. Leave GV2AUX→SDI RPS
Parameters→Call Back Enabled? at the default
value of No when using Version 7.05.
• The Command 43 RPS connect using the network
feature is not available in Version 7.05.
• When arming the last associate area from a D1260
or D1260B Keypad, any points that are not ready
to arm in a shared area are automatically
bypassed instead of force bypassed.