3.0 Known Issues in Firmware
Version 4.10
Multiplex Devices and Address 9995: To add
multiplex devices that do not have DIP switches,
use Address 9995. However, the first zone
displayed, Zone 009, is reserved for the first
DACM door contact. Press and hold [*] until
“MUX POINT” appears on the keypad’s display.
Enter the desired zone number for the multiplex
device.
Door Forced Open Condition Does Not Send a
Report: You must enable Addresses 3418
(Keypad Tamper) and 3419 (Keypad Tamper
Restoral) to send a Door Forced Open (DACM
Trouble 75) report.
DACM Trouble Events Do Not Show the
DACM Number: If a DACM experiences a
trouble event, such as a Tamper (72), Missing (73),
Door Held Open (74), or Door Forced Open (74),
the keypad does not show the number for that
DACM when it displays the trouble message.
Keypad and DACM Tamper and Restoral
Report Programming: Information on
programming keypad and DACM tamper and
restoral reports is missing from the control panel’s
documentation. Use Address 3418 for keypad or
DACM tamper reports, and Address 3419 for
keypad or DACM tamper restoral reports. If you
disable tamper and tamper restoral reports for
keypads, the keypads do not display tamper
messages. However, if you disable tamper and
tamper restoral reports for DACMs, the keypads
still display DACM tamper messages.
DX4010i Serial Interface Module “Printer
Error” Message: The control panel generates a
“Printer Error” message if you use the DX4010i to
create a direct connection to the remote
programming software (RPS) PC.
RPS Callback Address 3043: Enter an IP address
in Address 3043 if you want the control panel to
call the RPS PC over an Ethernet network.
Daylight Saving Time Missing from Reference
Guide: To enable Daylight Saving Time, set
Address 3478, Data Digit 2 to “1.” To disable
Daylight Saving Time, set Data Digit 2 to “0.”
Daylight Saving Time Not Working Correctly:
The Daylight Saving Time falls back an hour at
2:00 AM instead of 3:00 AM on the last Sunday in
October.
Network Communication Attempts Use
AltComm Module 2 First, Then AltComm
Module 1: The control panel uses AltComm
Module 2 first before using AltComm Module 1
when attempting to communicate over an
Ethernet network. When attempting to
communicate over the telephone line, the control
panel uses Phone 1 first before using Phone 2.
AltComm Remote Programming Callback Not
Available: You cannot program the control
panel for remote programming callback over an
Ethernet network.
Arming An Unlocked Door: You can arm an
area when a user command latches a door access
control module’s (DACM) door open, or a fire
alarm latches a DACM’s door open.
Fire Bell and DACM Operation: If the bell
output is set for fire and assigned to all areas
(partitions), then all DACMs in the system release
their doors during a fire alarm. If the bell output is
assigned to a certain area, only the DACMs in
that area release their doors.
Restoral Report Not Sent for Serial Interface
Module or AltComm Module: The control
panel does not send a restoral report when a serial
interface module, or an altcomm module with the
altcomm heartbeat parameter disabled, fails and
then restores.
Alarm Verification Not Available: Alarm
verification is not available in version 4.10 of the
DS7400XiV4.
“Do Not Use Central Station Ack” Option and
High Network Activity: Alarm reports sent over
an Ethernet network during periods of high
network activity might not reach the central
station if the “Do Not Use Central Station Ack”
option is selected. Refer to Table 5 on page 3 for
more information.