Notice
Use at least one keypad in each system.
Area Configurations
Area programming offers a wide selection of different
system configurations. Each area is assigned an
account number to define annunciation, control, and
reporting functions. Multiple areas can be linked to a
shared area which is automatically controlled (hallway
or lobby). Area arming can be conditional on other
areas (master or associate).
Two Man Rule
Two Man Rule provides added security by requiring:
Two people present at opening
Two unique passcodes on the same keypad to disarm
an area
Without the second passcode, the system denies
entry.
Early Ambush
Early Ambush requires two passcode entries on the
same keypad. Enter the same passcode twice or have
two unique passcodes, depending on the
configuration. The first entry disarms the area and the
second entry stops a timer programmed to send a
duress event. If the second entry does not occur
within the programmed time, the system generates a
duress event. Early Ambush allows users to inspect the
premises and use the system to confirm that the area
is safe to enter, providing added security.
Easy Exit Control
The D9412GV2 Control Panel changes from one armed
state to another armed state without disarming. For
example, if you change the state from Master Arm to
Perimeter Arm, the control panel complies and reports
the change. Easy Exit Control reduces the number of
keystrokes, simplifying system operation.
Programmable Passcode‑controlled Menu List
The system prompts users to enter a passcode prior to
viewing the keypad menu. The keypad display shows
the user the menu options allowed according to the
user’s authority level. Passcode-controlled menus
provide users only with the options and information
pertinent to them, simplifying system operation.
Passcode Follows Scope
Use Passcode Follows Scope to restrict passcode
arming and disarming to the keypad's immediate local
area, even if the keypad can report events from other
areas. Passcode Follows Scope simplifies the arming
and disarming procedure without limiting any other
keypad capabilities.
Invisible Walk Test
A menu item allows the user to test invisible 24‑hour
points within the scope of the keypad without sending
a report to the central station.
Door‑Activated Custom Function
A custom function activates when user credentials are
presented to a D9210B door controller's reader. The
custom function behaves as though the user
performed a function at the keypad associated with
the door controller.
Passcodes
User passcodes contain three to six digits. Assign each
user one of 14 customized authority levels in each
area. Restrict passcodes to operate only during certain
times.
The Two Man Rule and Early Ambush options require
two passcodes, providing additional security in
financial establishments such as banks.
Communications
The D9412GV2 Control Panel prioritizes and sends
reports in BFSK or Modem IIIa
2
communications
formats to four route groups. Each group has a
programmable primary and backup destination.
The D9412GV2 works with the Conettix D6600
Communications Receiver/Gateway using a Conettix
DX4020 Network Interface Module. When using a
DX4020, the D9412GV2 has programmable anti-replay
anti-substitution features.
The Modem IIIa
2
Communications Format, available
with Bosch receivers, adds central station reporting
capabilities such as:
Individual point numbers and text
Opening or closing reports by area number
Remote programming attempts
Diagnostic reports
User name reports
Security and Fire Detection
The D9412GV2 Control Panel provides eight on‑board
points, and up to 238 additional off‑board points
(depending on model and expansion interfaces). You
can program individual points to monitor all types of
burglar alarms, fire alarms, and supervision devices.
Event Log
The event log stores up to 1,000 local and transmitted
events. The event log includes time, date, event, area,
point, and user number. View the event log from a
keypad or use RPS to remotely retrieve event
information. RPS operators can retrieve events
periodically using one phone call, rather than receiving
several calls each day. When the event log reaches a
programmed threshold of stored events, it can send an
optional report to a receiver.
Access Control
The D9412GV2 provides custom door strike, point
shunt and auto disarming response by area. There are
14 panel‑wide access levels with both manual and
scheduled control.
Store, view, or print access events such as:
Access granted
No entry
Request-to-enter
Request-to-exit
2
| D9412GV2 Control Panel