5.5 Codepad Programming
5.5.1 Codepad Duress
Location
476 to 479
Location Default
Contact ID Event Code
Hundreds 476 1
Tens 477 2
Units 478 1
Dialler Channel 479 1
5.5.2 Codepad Panic
Location
480 to 483
Location Default
Contact ID Event Code
Hundreds 480 1
Tens 481 2
Units 482 0
Dialler Channel 483 1
5.5.3 Access Denied (Code Retries)
Location
484 to 487
Location Default
Contact ID Event Code
Hundreds 484 4
Tens 485 2
Units 486 1
Dialler Channel 487 1
5.5.4 Codepad Lockout Time
Location
640 to 641
Location Default
Increments of 1 seconds
(0 seconds to 15 seconds)
640 0
Increments of 16 seconds
(0 seconds to 240 seconds)
641 0
5.6 AC Fail
Location
488 to 491
Location Default
Contact ID Event Code
Hundreds 488 3
Tens 489 0
Units 490 1
Dialler Channel 491 1
5.7 Low Battery
Location
492 to 495
Location Default
Contact ID Event Code
Hundreds 492 3
Tens 493 0
Units 494 9
Dialler Channel 495 1
5.8 Program Altered Code
Location
496 to 499
Location Default
Contact ID Event Code
Hundreds 496 3
Tens 497 0
Units 498 6
Dialler Channel 499 0
5.9 Sensor Watch (V1.10 to V1.31,
V1.32)
Location
500 to 503 (V1.10 to V1.31)
Location Default
Contact ID Event Code
Hundreds 500 3
Tens 501 8
Units 502 3
Dialler Channel 503 1
Location
500 to 503 (V1.32)
Location Default
Contact ID Event Code
Hundreds 500 3
Tens 501 0
Units 502 7
Dialler Channel 503 1
5.10 Reports Programming
5.10.1 Open/Close Reports for Area 1
Location
504 to 505
Location Default
Open Report 504 8
Close Report 505 9
5.10.2 Test Report Time (Automatic)
Location
506 to 513
Location Default
Hour of day (tens digit) 506 0
Hour of day (units digit) 507 0
Minute of day (tens digit) 508 0
Minute of day (units digit) 509 0
Repeat interval (tens digit) 510 0
Repeat interval (units digit) 511 0
Expansion code 512 9
Test Report options 513 0
1 Test Reports Only When Armed