CC880/LP880, SC8016 | Quick Reference Guide | 5. Programming Parameters EN | 10
Bosch Security Systems | 6/04 | 4998152461B
4.3.20 Codepad ID/Buzzer Tone
1. Press and hold the [8] key until the desired
buzzer tone is reached.
If the system is partitioned, the codepad displays
a number to identify which area the codepad
belongs to (see Table 7).
2. Press the [#] key to exit.
Table 7: Codepad ID/Buzzer Tone
Zone LED Codepad Assignment
1 Area 1
2 Area 2
3 Area 3
4 Area 4
7 Master Partitioned Codepad
4.3.21 Test Report
Press and hold the [9] key until two beeps sound.
4.3.22 Speaker Test
Press and hold the [1] key until two beeps sound. The
speaker sounds for two seconds.
4.3.23 Bell Test
Press and hold the [2] key until two beeps sound. The
piezo sounds for 2 seconds.
4.3.24 Strobe Test (Toggle On/Off)
Press and hold the [3] key until three beeps sound to
turn the strobe on.
Or
Press and hold the [3] key until two beeps sound to
turn the strobe off.
5. Programming Parameters
Shaded rows indicate default values.
5.1 Telephone Programming
5.1.1 Primary Telephone Number
Location
000 to 015
Default
0
0 = 10 and telephone termination = 0
Anywhere else 0 = 0
5.1.2 Secondary Telephone Number
Location
016 to 031
Default
0
0 = 10 and telephone termination = 0
Anywhere else 0 = 0
5.1.3 Call Back Telephone Number
Location
032 to 047
Default
0
0 = 10 and telephone termination = 0
Anywhere else 0 = 0
5.1.4 Dialling Format
Location
048
1 Australian DTMF
2 Australian decadic
3 Alternate DTMF and decadic (Aust)
4 International DTMF
5 Reversed decadic
6 Alternate DTMF and reversed decadic
5.1.5 Handshake Tone
Location
049
1 HI-LO handshake (contact ID)
2 1400 Hz (Ademco TX @ 1900 Hz)
3 2300 Hz (Sescoa TX @ 1800 Hz)
4 No handshake
5 Pager
5.1.6 Transmission Format
Location
050
1 Contact ID
2 4 + 2 expressed
3 4 + 2 pulsed
4 4 + 2 pulsed + checksum
5 4 + 1 pulsed + universal
6 4 + 1 pulsed expanded
7 3 + 1 pulsed universal
8 3 + 1 pulsed expanded
9 Reserved
10 Reserved
11 Domestic
12 Basic pager
13 Reserved
14 PET alpha pager
15 Synthesised voice
5.1.7 Transmission Speed
Location
051
1 1 pulse/second
2 10 pulses/second
3 15 pulses/second
4 20 pulses/second
5 20 pulses/second FDL
6 40 pulses/second
5.1.8 Subscriber ID Number For Area 1
Location
052 to 055
Default
0
5.1.9 Installer Code
Location
056 to 062
Location Default
056 1
057 2
058 3
059 4
060 15
061 15
062 15