PRE-
INSTALLATION
INSTALLATION INSTRUCTIONS
5
TERMINAL OUTLET POSITIONS
8 718 682 335b (09.2008)
REDIRECTING THE FLUE DISCHARGE:
The Telescopic flue terminal plume deflector
can be adjusted to redirect the flue discharge
allowing some plume management control,
alternatively, a complete plume management
system can be fitted to the flue terminal.
The flue terminal outlet position must
follow those stated in the relevant
appliance Instruction Manual and when
redirecting the flue discharge the outlet
terminal must also be at least 1500mm
from any opening in the direction of the
discharge to prevent combustion
products from entering the building, as
shown.
TERMINAL OUTLET POSITIONS
REDIRECTING FLUE DISCHARGE FROM A
Ø60/100mm TELESCOPIC FLUE TERMINAL
Plume deflector
Min.
1500mm
Opening in
building
Direction of flue
discharge