Connecting the alarm output
Danger!
Electrical voltage.
Risk of electric shock and damage to the unit.
The contacts must not be used at AC line voltages.
The alarm output relays respond to input alarms and triggers. Only connect resistive loads to
the alarm output relays. To avoid overloading, always make sure the relay has the following
specifications.
Relay Specification
Model JRC-27F
Touch material Silver
Rating (resistance load) Rated switch capacity 30 VDC 2 A, 125 VAC 1 A
Maximum switch power 125 VA 160 W
Maximum switch voltage 250 VAC, 220 VDC
Maximum switch current 1 A
Power supply
DIVAR 3000
DC power is supplied from an AC/DC power supply unit delivered with the unit. The unit has
its own on/off switch to turn power supply off and on.
Specifications:
External power supply unit:
AC input: 100-240 VAC; 1.7 A; 50/60 Hz
DC output: 12 VDC; 5 A
DIVAR power input: 12 VDC; 3.5 A
DIVAR 5000
Power is supplied from an AC power supply. The unit has its own on/off switch to turn power
supply off and on.
Specifications:
Power supply: AC input: 100-240 VAC; 1.7 A; 50/60 Hz