8 Troubleshooting
8.1 Illuminator Operation
The following table is intended to help you identify the causes of malfunctions and correct
them when possible.
Issue Possible Solution
Fuse blows – Check the fuse rating.
– Check for shorting between the housing and the input power
wires.
Cannot tell if LEDs
are ON
850 nm LEDs will have a faint red glow when ON.940nm LEDs are
covert. To check:
– Aim the LEDs directly at an IR sensitive camera, or
– Wait for the LEDs to warm up (two minutes).
LEDs are not ON – Cover the photocell to activate power to the LEDs (up to 30
seconds delay for activation).
– Adjust the photocell sensitivity control. See
Section 6 Configuration, page 20.
– Adjust power to the LEDs.
LEDs do not turn
OFF when sufficient
ambient light is
present
– Make sure the photocell is not covered or hidden behind any
object.
– Adjust the photocell sensitivity control. See
Section 6 Configuration, page 20. The LEDs remain ON or OFF if
the adjustment is at full turn.
LEDs oscillating ON
and OFF
– Adjust the photocell sensitivity control. See
Section 6 Configuration, page 20.
– Remove any objects in front of the LEDs that are causing
reflections back to the photocell sensor.