Bosch DS7400Xi Specifikace Strana 44

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 101
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 43
© Radionics Inc. reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as copying and passing on to third parties.
44
.
DS7400Xi Panel Wiring & Programming
Programming A Zone
Default Values
(Will be forced to different values when in
Commercial Fire Mode. See Sec 11.15.3)
.
Value Zone Address
(Fill in) Function
1 0001 2 = Steady Alarm Output, alarm on short & open
3 = Entry/Exit Delay 1
2 0002 2 = Steady Alarm Output, alarm on short & open
4 = Entry/Exit Delay 2
3 0003 2 = Steady Alarm Output, alarm on short & open
1 = Perimeter Instant
4 0004 2 = Steady Alarm Output, alarm on short & open
5 = Interior Entry/Exit Follower
5 0005 2 = Steady Alarm Output, alarm on short & open
6 = Interior Home/Away
6 0006 2 = Steady Alarm Output, alarm on short & open
7 = Interior Instant
7 0007 2 = Steady Alarm Output, alarm on short & open
2 = 24-Hour
8 0008 2 = Pulsing Alarm Output, alarm on short; trouble
on open. *0 = Fire Zone with Verification
Zobrazit stránku 43
1 2 ... 39 40 41 42 43 44 45 46 47 48 49 ... 100 101

Komentáře k této Příručce

Žádné komentáře