DS7400Xi Panel Wiring & Programming
Programming A Zone
Default Values
(Will be forced to different values when in
Commercial Fire Mode. See Sec 11.15.3)
.
Value Zone Address
(Fill in) Function
1 0001 2 = Steady Alarm Output, alarm on short & open
3 = Entry/Exit Delay 1
2 0002 2 = Steady Alarm Output, alarm on short & open
4 = Entry/Exit Delay 2
3 0003 2 = Steady Alarm Output, alarm on short & open
1 = Perimeter Instant
4 0004 2 = Steady Alarm Output, alarm on short & open
5 = Interior Entry/Exit Follower
5 0005 2 = Steady Alarm Output, alarm on short & open
6 = Interior Home/Away
6 0006 2 = Steady Alarm Output, alarm on short & open
7 = Interior Instant
7 0007 2 = Steady Alarm Output, alarm on short & open
2 = 24-Hour
8 0008 2 = Pulsing Alarm Output, alarm on short; trouble
on open. *0 = Fire Zone with Verification