Connection to Video Streaming Gateway
TCP port 8756
Connection to (Enterprise ) Management Server:
TCP ports 5390, 5392, 5393, 5395, 5396
Connection to Operator Client Workstations by BVMS SDK:
TCP port (default 5394)
Connection from Management Server to SMTP (for email notifications):
TCP port 25
Connection to Bosch encoders and decoders:
Control channel: TCP ports 80 and 1756
Network scan: UDP ports 1757 and 1758
Multicast detection: one selectable UDP port (default 1800)
Multicast video transmission:
For each encoder audio or video stream, 1 selectable UDP port
Unicast UDP transmission: UDP ports dynamically assigned in the range
from 1024 to 65000
Connection between Management Server and DiBos (as of V.8.10.,
earlier versions need a patch for using Web service):
TCP port 808
Connection between Operator Client and DiBos DVRs (uses DCOM):
TCP Port 135 plus four TCP ports and four UDP ports dynamically
assigned in the range from 1025 to 65535
These ports are also used when Management Server and an old DiBOS
8.9 or earlier without patch are connected.
Management Server Specifications
Maximum number of sustained
events
For highest performance server:
500 events/s with Logbook
1000 events/s without Logbook
5000 events/s at peaks with
Logbook
Logbook Supported by SQL Server 2008
R2 (64-bit version)
4 GByte Logbook size
Management Server Redundancy Available with VMware HA.
Please contact Bosch Design
Engineer for redundancy
solutions.
Maximum number of Task
Schedules
200
VRM Specifications
Maximum count of VRM servers
per Management Server
40
Maximum data rate per iSCSI Please contact Bosch Design
Engineer for iSCSI storage
solutions.
Max. number of playback sessions 64
Minimum Client Workstation PC Requirements
Operation System Windows 7 Professional or
Ultimate SP1 64 bit version
(required for > 500 cameras)
CPU Intel Core 2 Duo
RAM 2 GB or greater
4 GB or greater for Enterprise
Operator Clients
Free disk space 3 GB or more for Single Site
Systems
5 GB or more for Enterprise
Systems
We recommend having minimum
15% free disk space.
Network card 1000Base-T
Display Resolution Minimum per monitor
1024x768, 1280x1024 or
greater recommended
Recommended Graphic Card MHW-AWGC-Q4000
MHW-AWGC-Q5000
Maximum Graphic Cards Specifications
You find detailed information on the maximum number
of Image panes and the CPU load for various
workstations or servers and graphic cards in the
Application Guide “Display performance indication”.
Minimum Management Server PC Requirements
Operation System Windows 2008 Server R2 SP1
(64-bit) required for > 500
cameras
Window 2003 Server R2 SP2
(32-bit only) for NVR only
For All-in-one systems and
maximum 64 IP cameras/
encoders:
Windows 7 Professional or
Ultimate SP1 (64-bit only)
CPU Intel Core 2 Duo
Intel Core 2 Quad for systems >
500 cameras
RAM 4 GB or greater
8 GB for systems > 500 cameras
Free disk space 15 GB or greater
We recommend having minimum
15% free disk space.
Network card 1000Base-T
Display Resolution 1024x768 or greater
Minimum VRM Server PC Requirements
Operation System Windows 7 Ultimate SP1,
Professional Edition SP1 64-bit
versions
Windows Server 2003 R2,
Standard Edition, 64-bit versions
Windows Server 2008 R2,
Standard Edition 64-bit versions
Windows Storage Server 2008,
Standard Edition 64-bit versions
CPU Dual-Core Intel Xeon Processor
5110 (1.60 GHz, 1066 FSB) to
Quad-Core Intel Xeon Processor
E5430 (2.66 GHz, 1,333 FSB)
4 | Bosch Video Management System v.4
Komentáře k této Příručce