D720 Series | Installation Guide | 8.0 How to customize User’s Guide for System Owner
Bosch Security Systems | 8/04 | 74-06918-000-F 7
7.4 System Commands Supported by
the D720 Series
The following commands are supported by the D720
Series:
Table 6: Keypad supported commands
Function Command
Bypass a Point CMD 0
Unbypass a Point CMD 00
Master Arm CMD 1
Master Arm Instant CMD 11
Perimeter Instant CMD 2
Perimeter Delay CMD 3
Send Report CMDs 41 & 42
Remote Program CMD 43
Walk Test CMD 44
Reset Sensors CMD 47
Delete Passcode CMD 53
Change Passcode CMD 55
Fire Test CMD 58
Watch Mode CMD 6
User Command 7 CMD 7
Perimeter Partial CMD 8
User Command 9 CMD 9
8.0 How to customize User’s
Guide for System Owner
In the D720 Series User’s Guide (P/N: 71-06898-000),
check the appropriate boxes on the pages describing
system commands so the end user knows
a. whether a function is available and
b. whether a passcode is required for the
function.
9.0 Specifications
Table 7: D720 Series Specifications
Operating
Voltage
Nominal 12 VDC
Keypad Idle 20 mA Current
Requirements
Maximum 100 mA
Dimensions
(H x W x D)
4.6 in. x 8.2 in. x 0.8 in.
(11.7 cm x 20.8 cm x 20.8 cm)
Wiring A four-conductor, quick-connect, plug-
in cable is provided for interfacing with
the compatible control panels (refer to
Table 1)
Operating
Temperature
+32°F to +122°F
(0°C to +50°C)
Non-condensing
Relative Humidity
5% to 85% @ +86°F (+30°C)
Komentáře k této Příručce